Performances

  • Air water wind

    The Air Water Wind performance groups the specific characteristics of the tightness levels according to standards EN 1027 and EN 12208 for watertightness, EN 1026 and EN 12207 for airtightness and wind resistance.

  • Thermal insulation

    The thermal insulation performance complies with the European standards EN 10077-1 and EN 10077-2 for the thermal-transmission capacity.

  • Anti-panic

    The anti-panic performance refers to European standards EN 179 and EN 1125 that are specific to the special transit conditions in buildings in the event of evacuation.

COMBINED AND CERTIFIED PERFORMANCE Laboratory tested

Single doorsDouble doorsFixed frames
Burglary resist.
RC3 (+FB4)RC3RC3
RC4RC4RC4 (+FB6)
--CR5 + AK47 + MBE3
Bullet-proof
FB4 FB4 FB4
--AK47 + RC4 + MBE3
FB5*FB5*FB5*
FB6 (+RC4)FB6 (+RC4)FB6 (+RC4)
FB7 + RC4 -FB7 + RC4
Fire resistance
EI1 30 (+RC2) (+RC3)EI1 30 (+RC2) (+RC3)EI 30 (+RC2) (+RC3)
EI2 30 (+RC2) (+RC3)EI2 30 (+RC2) (+RC3)
EI1 60EI1 60EI 60 (+RC2) (+RC3)
EI2 60EI2 60
EI2 90EI2 90EI 90
--EI 120

*under conditions - (+XXX) = optional option - RC2 and other performances upon request